certificate:
  number: R61/2017-A-DK2-22.01
  scheme: A
  member_state: Denmark
  date_issued: '2022-06-17'
  oiml_issuer_id: DK2
issuing_authority:
  name: FORCE Certification A/S
  address_lines:
  - Park Allé 345
  - 2605 Brøndby
  - Denmark
  person_responsible: Per Rafn Crety
  person_title: N/A
  phone: N/A
  email: N/A
  website: N/A
  oiml_issuer_id: DK2
applicants:
- name: Flintec UK Ltd.
  address_lines:
  - Caxton House
  - Caxton Place
  - Pentwyn
  - Cardiff CF23 8HG
  - United Kingdom
manufacturers:
- name: Flintec UK Ltd.
  address_lines:
  - Caxton House
  - Caxton Place
  - Pentwyn
  - Cardiff CF23 8HG
  - United Kingdom
certified_type:
  category: Weighing transmitter
  type_designations:
  - ER500-F
  module_designation: weighing_transmitter
characteristics:
  type_level:
    type:
      value: ER500-F
    reference_class:
      value: Ref(0.5)
    accuracy_class:
      value: N/A
    maximum_number_of_verification_scale_intervals_ni:
      value: "≤3×10000"
    maximum_tare_effect:
      value: "-Max"
    fractional_factor_pi:
      value: 0.5
    minimum_input_voltage_per_vsi:
      value: 0.2
      unit_symbol: μV
      unit_id: u:volt
    warm_up_time:
      value: 3
    maximum_time_between_automatic_zero_setting:
      value: 120
    power_supply_voltage:
      value:
        min: 5
        max: 5
      unit_symbol: VDC
      unit_id: u:volt
    load_cell_interface:
      value: 4-wire or 6-wire
    minimum_input_impedance:
      value: 43
      unit_symbol: ohm
      unit_id: u:ohm
    maximum_input_impedance:
      value: 1200
      unit_symbol: ohm
      unit_id: u:ohm
    mains_power_supply:
      value:
        min: 9.0
        max: 32.0
    operational_temperature:
      value:
        min: -15
        max: 55
      unit_symbol: "°C"
      unit_id: u:degree_Celsius
    maximum_cable_length_between_er500_f_and_junction_box:
      value: 1533
  model_level: []
  config_level: []
recommendation:
  id: R61
  edition: 2017
  scheme: A
  accuracy_classes:
  - Ref(0.5)
  - X(0.5)
  - X(1)
  - X(2)
test_reports: []
revision_history:
- revision: Initial version
  date: '2022-06-17'
  changes: "-"
_traceability:
  raw_labels:
    mains_power_supply: mains_power_supply