certificate:
  number: R60/2021-A-DE1-24.01
  scheme: A
  member_state: Germany
  date_issued: 2024-10-24
  oiml_issuer_id: DE1
issuing_authority:
  name: Example Issuing Authority B.V.
  address_lines:
    - Example Street 1, 1234 Example City
  person_responsible: Dr. Jane Smith
  oiml_issuer_id: DE1
applicants:
  - name: 3 S Fabrications (Pvt) Ltd
    address_lines:
      - Venus Mills, Etiyawela, Daluwela
      - 61130 Dankotuwa
      - Sri Lanka
manufacturers:
  - name: 3 S Fabrications (Pvt) Ltd
    address_lines:
      - Venus Mills, Etiyawela, Daluwela
      - 61130 Dankotuwa
      - Sri Lanka
certified_type:
  category: Load cell
  type_designations:
    - RCMF
  module_designation: N/A
characteristics:
  type_level:
    accuracy_class:
      value: C
    max_load_cell_intervals_nlc:
      value: 3000
    apportionment_factor_plc:
      value: 0.8
    minimum_load_cell_verification_interval_vmin:
      value: Emax/14000
      footnote_markers:
        - a)
    maximum_number_of_load_cell_intervals_nlc:
      value: 3000
    classification_symbol:
      value: C3
  model_level:
    - attribute: maximum_capacity
      unit_symbol: t
      values:
        - model: Emax=25t
          value: 25
        - model: Emax=30t
          value: 30
        - model: Emax=50t
          value: 50
        - model: Emax=60t
          value: 60
        - model: Emax=75t
          value: 75
        - model: Emax=90t
          value: 90
      unit_id: u:metric_ton
  config_level: []
recommendation:
  id: R60
  edition: 2021
  scheme: A
  accuracy_classes:
    - C3
test_reports:
  - id: KBS2-4.3-TER-06.02.03/0341#0001-0015
    date: 2024-10-24
    pages: 7
    role: type_evaluation_report
  - id: ZDS-R60/2021-A-DE1-24.01
    date: 2024-10-24
    pages: 2
    role: documentation_file
revision_history:
  - revision: "0"
    date: 2024-10-24
    changes: Initial issuance
model_family:
  family_name: null
  models:
    - model_id: Emax=25t
    - model_id: Emax=30t
    - model_id: Emax=50t
    - model_id: Emax=60t
    - model_id: Emax=75t
    - model_id: Emax=90t
footnotes:
  - marker: a)