certificate:
  number: R21/2007-FR02-2015/01 rev 2
  scheme: A
  page_total: 15
  member_state: FRANCE
  date_issued: '2015-10-21'
  oiml_issuer_id: FR2
issuing_authority:
  name: Laboratoire National de Métrologie et d'Essais
  address_lines:
  - 1, rue Gaston Boissier - 75724 Paris Cedex 15
  person_responsible: Thomas LOMMATZSCH
  person_title: Responsable du Pôle Certification / Measuring Instruments Division Manager
  phone: 01 40 43 37 00
  email: info@lne.fr
  website: www.lne.fr
  oiml_issuer_id: FR2
applicants:
- name: Automatismes et Techniques Avancées SA
  address_lines:
  - 30 impasse du Nid ZA du Verdalai
  - FRA 13790 PEYNIER
manufacturers:
- name: AUTOMATISMES ET TECHNIQUES AVANCEES SA
  address_lines:
  - 30 impasse du nid - ZA du Verdalai
certified_type:
  category: Taximeter
  type_designations:
  - A.T.A. type Révolution
  - taximeter A.T.A. type Revolution
  module_designation:
  description: >-
    The taximeter ATA type REVOLUTION indicates at any moment, the price to be paid by users depending on the distance covered,
    how long the vehicle is engaged and the programmed tariffs. The taximeter is composed by two elements: the ATA BOX and
    the ATA screen being the Human Machine Interface.
characteristics:
  type_level:
    voltage_supply_range:
      value:
        min: 9
        max: 16
      unit_symbol: V
      unit_id: u:volt
    k_constant_range:
      value:
        min: 500
        max: 120000
      unit_symbol: imp/km
      unit_id: u:impulse_per_kilometer
    mechanical_environment_class:
      value: M3
    electromagnetic_environment_class:
      value: E3
    temperature_range:
      value:
        min: -25
        max: 70
      unit_symbol: "°C"
      unit_id: u:degree_Celsius
  model_level: []
  config_level: []
recommendation:
  id: R21
  edition: 2007
  scheme: A
  accuracy_classes: []
test_reports: []
revision_history:
- revision: '0'
  date: '2015-04-24'
  changes: Initial
- revision: '1'
  date: '2015-10-09'
  changes: |-
    Change the value of the taximeter checksum
    Possibility to connect an ATA Cardan generator to the taximeter
    New appendix added: Appendix 2 Power UP
- revision: '2'
  date: '2015-10-21'
  changes: |-
    New appendix added: Appendix 3 Air S
    Appendix 4 Air W
model_family:
  family_name:
  models:
  - Screen Lite Pad
  - Screen PowerUP
  - Screen Air S
  - Screen Air W
components:
- role: Main unit
  type_designations:
  - ATA BOX
  characteristics: {}
- role: Human Machine Interface
  type_designations:
  - ATA screen
  characteristics: {}
matrix_tables:
- name: Error messages
  columns:
  - screen_code
  - description
  rows:
  - screen_code:
      value: "[CODE_MESS_DEFAULT]"
    description:
      value: Fault message position
  - screen_code:
      value: "[CODE_MESS_DEF_CAI]"
    description:
      value: 'Anomaly of sensor signal: instant acceleration'
  - screen_code:
      value: "[CODE_MESS_DEF_CAM]"
    description:
      value: 'Anomaly of sensor signal: mean acceleration'
  - screen_code:
      value: "[CODE_MESS_DEF_CU]"
    description:
      value: 'Anomaly of sensor signal: sudden acceleration'
  - screen_code:
      value: "[CODE_MESS_DEF_CP]"
    description:
      value: 'Anomaly of sensor signal: disturbance'
  - screen_code:
      value: "[CODE_MESS_DEF_CT]"
    description:
      value: 'Anomaly of sensor signal: amplitude'
  - screen_code:
      value: "[CODE_MESS_DEF_CIH]"
    description:
      value: 'Anomaly of sensor signal: high level impedance'
  - screen_code:
      value: "[CODE_MESS_DEF_CIB]"
    description:
      value: 'Anomaly of sensor signal: low level impedance'
  - screen_code:
      value: "[CODE_MESS_DEF_CIA]"
    description:
      value: 'Anomaly of sensor signal: stop impedance'
  - screen_code:
      value: "[CODE_MESS_DEF_CS]"
    description:
      value: 'Anomaly of sensor signal: stability'
  - screen_code:
      value: "[CODE_MESS_DEF_CL]"
    description:
      value: 'Anomaly of sensor signal: pulse width'
  - screen_code:
      value: "[CODE_MESS_DEF_CR]"
    description:
      value: 'Anomaly of sensor signal: duty cycle'
  - screen_code:
      value: "[CODE_MESS_DEF_CANBUS]"
    description:
      value: 'Anomaly of sensor signal: CAN Bus'
  - screen_code:
      value: "[CODE_NOTIF_PB_IMP]"
    description:
      value: 'Anomaly of printer: connection problem or missing paper'
  - screen_code:
      value: "[CODE_MESS_DEF_LA]"
    description:
      value: 'Anomaly of removable roof light: missing roof light'
  - screen_code:
      value: "[CODE_MESS_DEF_LE]"
    description:
      value: 'Anomaly of removable roof light: disconnected during a trip'
  - screen_code:
      value: "[CODE_MESS_DEF_LU]"
    description:
      value: 'Anomaly of removable roof light: Unrecognized device'
  - screen_code:
      value: "[CODE_NOTIF_PB_LUM]"
    description:
      value: Anomaly of roof light
  - screen_code:
      value: "[CODE_NOTIF_PB_PILE]"
    description:
      value: Anomaly of internal battery
  description: Error messages and their descriptions
  footnotes: []
- name: Revision history
  columns:
  - certificat_number
  - date
  - revision
  - object
  rows:
  - certificat_number:
      value: R21/2007-FR02-2015/01
    date:
      value: 24th, April 2015
    revision:
      value: '0'
    object:
      value: Initial
  - certificat_number:
      value: R21/2007-FR02-2015/01
    date:
      value: '09th, October 2015'
    revision:
      value: '1'
    object:
      value: |-
        Change the value of the taximeter checksum
        Possibility to connect an ATA Cardan generator to the taximeter
        New appendix added: Appendix 2 Power UP
  - certificat_number:
      value: R21/2007-FR02-2015/01
    date:
      value: 21th, October 2015
    revision:
      value: '2'
    object:
      value: |-
        New appendix added: Appendix 3 Air S
        Appendix 4 Air W
  description: Historical revisions of the certificate
  footnotes: []