Skip to content
CNMLCertificat Numérique de Métrologie Légale
← All certificates

R117 — OIML R117 (Dynamic Measuring Systems for Liquids Other than Water) Certificate Schema

Fuel & Flow · 3 samples
Sample 1
R117/2019-A-CZ1-25.01
Rev. 0 · 15 type_level characteristics
Issuer
Czech Metrology Institute
Date issued
2025-05-13
Type designations
ET-B, ET-C, ET-F
Category
Fuel dispenser
Full YAML
{
  "certificate": {
    "number": "R117/2019-A-CZ1-25.01",
    "scheme": "A",
    "page_total": 1,
    "member_state": "Czech Republic",
    "date_issued": "2025-05-13",
    "oiml_issuer_id": "CZ1"
  },
  "issuing_authority": {
    "name": "Czech Metrology Institute",
    "address_lines": [
      "Okružní 31",
      "638 00 Brno",
      "Czech Republic"
    ],
    "person_responsible": "Jan Kalandra",
    "person_title": "Person responsible",
    "phone": "N/A",
    "email": "N/A",
    "website": "N/A",
    "oiml_issuer_id": "CZ1"
  },
  "applicants": [
    {
      "name": "WENZHOU ECOTEC ENERGY EQUIPMENT CO. LTD",
      "address_lines": [
        "1901-1902 Digital Mansion Xincheng Avenue,Lucheng District",
        "Wenzhou,Zhejiang",
        "China"
      ]
    }
  ],
  "manufacturers": [
    {
      "name": "WENZHOU ECOTEC ENERGY EQUIPMENT CO. LTD",
      "address_lines": [
        "1901-1902 Digital Mansion Xincheng Avenue,Lucheng District",
        "Wenzhou,Zhejiang",
        "China"
      ]
    }
  ],
  "certified_type": {
    "category": "Fuel dispenser",
    "type_designations": [
      "ET-B",
      "ET-C",
      "ET-F"
    ],
    "module_designation": null,
    "description": "The ET-B, ET-C and ET-F fuel dispensers are designed for measurement of liquid fuel volumes and are used for the refuelling of motor vehicles, small boats and small aircrafts."
  },
  "characteristics": {
    "type_level": {
      "maximum_flow_rate": {
        "value": {
          "min": 50,
          "max": 50
        },
        "unit_symbol": "L/min",
        "unit_id": "u:liter_per_minute"
      },
      "minimum_flow_rate": {
        "value": {
          "min": 5,
          "max": 5
        },
        "unit_symbol": "L/min",
        "unit_id": "u:liter_per_minute"
      },
      "min_measured_quantity": {
        "value": 5,
        "unit_symbol": "L",
        "unit_id": "u:liter"
      },
      "accuracy_class": {
        "value": "0.5"
      },
      "liquids": {
        "value": "Gasoline, Diesel, Kerosene"
      },
      "temperature_range": {
        "value": {
          "min": -5,
          "max": 35
        },
        "unit_symbol": "°C",
        "unit_id": "u:degree_Celsius"
      },
      "ambient_temperature_range": {
        "value": {
          "min": -25,
          "max": 55
        },
        "unit_symbol": "°C",
        "unit_id": "u:degree_Celsius"
      },
      "maximum_pressure": {
        "value": 0.3,
        "unit_symbol": "MPa",
        "unit_id": "u:pascal"
      },
      "minimum_pressure": {
        "value": 0.12,
        "unit_symbol": "MPa",
        "unit_id": "u:pascal"
      },
      "environmental_classes": {
        "value": {
          "mechanical": "M1",
          "electromagnetic": "E1",
          "humidity": "H3"
        }
      },
      "measurement_unit": {
        "value": "Volume [L]"
      },
      "type_of_display": {
        "value": "Electronic"
      },
      "scale_interval_of_the_indication": {
        "value": 0.01,
        "unit_symbol": "L",
        "unit_id": "u:liter"
      },
      "software_identification": {
        "value": "Main board software version: MV302_6_1\nKey board software version: 17305"
      },
      "wm_checksum_crc": {
        "value": "A6D5"
      }
    },
    "model_level": [],
    "config_level": []
  },
  "recommendation": {
    "id": "R117",
    "edition": 2019,
    "scheme": "A",
    "accuracy_classes": [
      "0.5"
    ]
  },
  "test_reports": [
    {
      "id": "0511-ER-F045-23",
      "date": "N/A",
      "pages": 1,
      "role": "type_evaluation_report"
    },
    {
      "id": "6015-PT-P0023-25",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "6011-PT-SW009-25",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "8551-PT-E0318-24",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "0511-UL-F045-23",
      "date": "N/A",
      "pages": 1,
      "role": "documentation_file"
    }
  ],
  "revision_history": [
    {
      "revision": "0",
      "date": "2025-05-13",
      "changes": "Issuing of certificate"
    }
  ],
  "components": [
    {
      "role": "Measuring sensor",
      "type_designations": [
        "FM01"
      ],
      "characteristics": {}
    },
    {
      "role": "Pulser",
      "type_designations": [
        "P2"
      ],
      "characteristics": {}
    },
    {
      "role": "Calculating / indicating device",
      "type_designations": [
        "WB"
      ],
      "characteristics": {}
    }
  ],
  "_traceability": {
    "raw_labels": {
      "ambient_temperature_range": "ambient_temperature_range"
    }
  }
}
Sample 2
R117/2019-A-CZ1-25.02
Rev. 0 · 16 type_level characteristics
Issuer
Czech Metrology Institute
Date issued
2025-06-25
Type designations
INNO 2000(B-E-EC-I), INNO 3000(B-E), INNO 5000(H), INNO 6000(L-S-M-N)
Category
Fuel dispenser
Full YAML
{
  "certificate": {
    "number": "R117/2019-A-CZ1-25.02",
    "scheme": "A",
    "page_total": 1,
    "member_state": "Czech Republic",
    "date_issued": "2025-06-25",
    "oiml_issuer_id": "CZ1"
  },
  "issuing_authority": {
    "name": "Czech Metrology Institute",
    "address_lines": [
      "Okružní 31",
      "638 00 Brno",
      "Czech Republic"
    ],
    "person_responsible": "Jan Kalandra",
    "person_title": "N/A",
    "phone": "N/A",
    "email": "N/A",
    "website": "N/A",
    "oiml_issuer_id": "CZ1"
  },
  "applicants": [
    {
      "name": "Mithra Petrol Ekipmanları Ithalat Ihracat San.Tic.LTD.STI.",
      "address_lines": [
        "FEVZICAKMAK MAH.10757.SK.B BLOK NO:6D",
        "Karatay Konya",
        "Turkiye"
      ]
    }
  ],
  "manufacturers": [
    {
      "name": "Mithra Petrol Ekipmanları Ithalat Ihracat San.Tic.LTD.STI.",
      "address_lines": [
        "FEVZICAKMAK MAH.10757.SK.B BLOK NO:6D",
        "Karatay Konya",
        "Turkiye"
      ]
    }
  ],
  "certified_type": {
    "category": "Fuel dispenser",
    "type_designations": [
      "INNO 2000(B-E-EC-I)",
      "INNO 3000(B-E)",
      "INNO 5000(H)",
      "INNO 6000(L-S-M-N)"
    ],
    "module_designation": "N/A",
    "description": "The INNO 2000 (B-E-EC-I), INNO 3000 (B-E), INNO 5000 (H) and INNO 6000 (L-S-M-N) fuel dispensers are designed for measurement of liquid fuel volumes and are used for the refuelling of motor vehicles, small boats and small aircrafts."
  },
  "characteristics": {
    "type_level": {
      "pattern_designation": {
        "value": "INNO series"
      },
      "max_flow_rate_qmax": {
        "value": 50,
        "unit_symbol": "L/min",
        "unit_id": "u:liter_per_minute"
      },
      "min_flow_rate_qmin": {
        "value": 5,
        "unit_symbol": "L/min",
        "unit_id": "u:liter_per_minute"
      },
      "min_measured_quantity_mmq": {
        "value": 5,
        "unit_symbol": "L",
        "unit_id": "u:liter"
      },
      "accuracy_class": {
        "value": "0.5"
      },
      "liquids": {
        "value": "Gasoline, Diesel, Kerosene"
      },
      "temperature_range": {
        "value": {
          "min": -5,
          "max": 35
        },
        "unit_symbol": "°C",
        "unit_id": "u:degree_Celsius"
      },
      "ambient_temperature_range": {
        "value": {
          "min": -25,
          "max": 55
        },
        "unit_symbol": "°C",
        "unit_id": "u:degree_Celsius"
      },
      "maximum_pressure": {
        "value": 0.35,
        "unit_symbol": "MPa",
        "unit_id": "u:pascal"
      },
      "minimum_pressure": {
        "value": 0.03,
        "unit_symbol": "MPa",
        "unit_id": "u:pascal"
      },
      "environmental_classes": {
        "value": {
          "mechanical": "M1",
          "electromagnetic": "E1",
          "humidity": "H3"
        }
      },
      "measurement_unit": {
        "value": "Volume [L]"
      },
      "type_of_display": {
        "value": "Electronic"
      },
      "scale_interval_of_the_indication": {
        "value": 0.01,
        "unit_symbol": "L",
        "unit_id": "u:liter"
      },
      "software_identification": {
        "value": "2.0.2"
      },
      "w_m_checksum_crc": {
        "value": "3C03"
      }
    },
    "model_level": [],
    "config_level": []
  },
  "recommendation": {
    "id": "R117",
    "edition": 2019,
    "scheme": "A",
    "accuracy_classes": [
      "0.5"
    ]
  },
  "test_reports": [
    {
      "id": "0511-ER-F095-24",
      "date": "N/A",
      "pages": 1,
      "role": "type_evaluation_report"
    },
    {
      "id": "6015-PT-P0024-25",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "6011-PT-SW014-25",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "8551-PT-E0083-25",
      "date": "N/A",
      "pages": 1,
      "role": "test_report"
    },
    {
      "id": "0511-UL-F095-24",
      "date": "N/A",
      "pages": 1,
      "role": "documentation_file"
    }
  ],
  "revision_history": [
    {
      "revision": "0",
      "date": "2025-06-25",
      "changes": "Issuing of certificate"
    }
  ],
  "components": [
    {
      "role": "Measuring sensor",
      "type_designations": [
        "MTH-65"
      ],
      "characteristics": {}
    },
    {
      "role": "Pulser",
      "type_designations": [
        "MD-212/100/DC5/S2"
      ],
      "characteristics": {}
    },
    {
      "role": "Calculating / indicating device",
      "type_designations": [
        "EFSC PLUS"
      ],
      "characteristics": {}
    }
  ],
  "_traceability": {
    "raw_labels": {
      "ambient_temperature_range": "ambient_temperature_range"
    }
  }
}
Sample 3
R117/2019-A-CZ1-25.03
Rev. 0 · 7 type_level characteristics
Issuer
Czech Metrology Institute
Date issued
2025-06-25
Type designations
SG 01(B-E-EC-I), SG 02(B-E), SG 03(H), SG 04(L-M)
Category
Fuel dispenser
Full YAML
{
  "certificate": {
    "number": "R117/2019-A-CZ1-25.03",
    "scheme": "A",
    "page_total": 1,
    "member_state": "Czech Republic",
    "date_issued": "2025-06-25",
    "oiml_issuer_id": "CZ1"
  },
  "issuing_authority": {
    "name": "Czech Metrology Institute",
    "address_lines": [
      "Okružní 31",
      "638 00 Brno",
      "Czech Republic"
    ],
    "person_responsible": "Jan Kalandra",
    "person_title": "N/A",
    "phone": "N/A",
    "email": "N/A",
    "website": "N/A",
    "oiml_issuer_id": "CZ1"
  },
  "applicants": [
    {
      "name": "SAHM Gulf Industry Company",
      "address_lines": [
        "Saudi Arabia-hafar Albatin-Saudi Authority For Industril Cities(MODON)",
        "C.R 1010777207",
        "Saudi Arabia"
      ]
    }
  ],
  "manufacturers": [
    {
      "name": "SAHM Gulf Industry Company",
      "address_lines": [
        "Saudi Arabia-hafar Albatin-Saudi Authority For Industril Cities(MODON)",
        "C.R 1010777207",
        "Saudi Arabia"
      ]
    }
  ],
  "certified_type": {
    "category": "Fuel dispenser",
    "type_designations": [
      "SG 01(B-E-EC-I)",
      "SG 02(B-E)",
      "SG 03(H)",
      "SG 04(L-M)"
    ],
    "module_designation": null,
    "description": "The SG 01 (B-E-EC-I), SG 02 (B-E), SG 03 (H) and SG 04 (L-M) fuel dispensers are designed for measurement of liquid fuel volumes and are used for the refuelling of motor vehicles, small boats and small aircrafts. SG measuring system consists measuring transducer consisting of piston PD measurement sensor and pulse transmitter, solenoid valve, electronic calculating and indicating device, keypad, sight glass (optional) and hose with dispensing nozzle. The system is intended to be used with an external submersible pump placed at the bottom of a storage tank."
  },
  "characteristics": {
    "type_level": {
      "pattern_designation": {
        "value": "SG series"
      },
      "accuracy_class": {
        "value": "0.5"
      },
      "liquids": {
        "value": "Gasoline, Diesel, Kerosene"
      },
      "measurement_unit": {
        "value": "Volume [L]"
      },
      "type_of_display": {
        "value": "Electronic"
      },
      "software_identification": {
        "value": "2.0.2"
      },
      "w_m_checksum_crc": {
        "value": "3C03"
      }
    },
    "model_level": [
      {
        "attribute": "max_flow_rate_qmax",
        "unit_symbol": "L/min",
        "values": [
          {
            "model": "SG series",
            "value": 50
          }
        ],
        "unit_id": "u:liter_per_minute"
      },
      {
        "attribute": "min_flow_rate_qmin",
        "unit_symbol": "L/min",
        "values": [
          {
            "model": "SG series",
            "value": 5
          }
        ],
        "unit_id": "u:liter_per_minute"
      },
      {
        "attribute": "min_measured_quantity_mmq",
        "unit_symbol": "L",
        "values": [
          {
            "model": "SG series",
            "value": 5
          }
        ],
        "unit_id": "u:liter"
      },
      {
        "attribute": "temperature_range",
        "unit_symbol": "°C",
        "values": [
          {
            "model": "SG series",
            "value": {
              "min": -5,
              "max": 35
            }
          }
        ],
        "unit_id": "u:degree_Celsius"
      },
      {
        "attribute": "temperature_range",
        "unit_symbol": "°C",
        "values": [
          {
            "model": "SG series",
            "value": {
              "min": -25,
              "max": 55
            }
          }
        ],
        "unit_id": "u:degree_Celsius"
      },
      {
        "attribute": "maximum_pressure",
        "unit_symbol": "MPa",
        "values": [
          {
            "model": "SG series",
            "value": 0.35
          }
        ],
        "unit_id": "u:pascal"
      },
      {
        "attribute": "minimum_pressure",
        "unit_symbol": "MPa",
        "values": [
          {
            "model": "SG series",
            "value": 0.03
          }
        ],
        "unit_id": "u:pascal"
      },
      {
        "attribute": "environmental_classes",
        "values": [
          {
            "model": "SG series",
            "value": "M1, E1, H3"
          }
        ]
      },
      {
        "attribute": "scale_interval_of_the_indication",
        "unit_symbol": "L",
        "values": [
          {
            "model": "SG series",
            "value": 0.01
          }
        ],
        "unit_id": "u:liter"
      }
    ],
    "config_level": []
  },
  "recommendation": {
    "id": "R117",
    "edition": 2019,
    "scheme": "A",
    "accuracy_classes": [
      "0.5"
    ]
  },
  "test_reports": [
    {
      "id": "0511-ER-F096-24",
      "date": "N/A",
      "pages": 1,
      "role": "type_evaluation_report"
    },
    {
      "id": "0511-UL-F096-24",
      "date": "N/A",
      "pages": 1,
      "role": "documentation_file"
    }
  ],
  "revision_history": [
    {
      "revision": "0",
      "date": "2025-06-25",
      "changes": "Issuing of certificate"
    }
  ],
  "components": [
    {
      "role": "Measuring sensor",
      "type_designations": [
        "MTH-65"
      ],
      "characteristics": {}
    },
    {
      "role": "Pulser",
      "type_designations": [
        "MD-212/100/DC5/S2"
      ],
      "characteristics": {}
    },
    {
      "role": "Calculating / indicating device",
      "type_designations": [
        "EFSC PLUS"
      ],
      "characteristics": {}
    }
  ],
  "_traceability": {
    "raw_labels": {
      "software_identification": "approved_software_versions"
    }
  }
}